Przeglądanie stron 1
2 947100
V-2006A, 6 zones with all call, up to 3 group
calls, override capabilities, background music
capabilities, two integrated tone generators for
night ringing and time clock tones plus integrated
power supply.
V-2920*, 20 zones with all call, background
music capabilities.
V-1109RTVA, 9 zones with all call.
V-119RTVA, 19 zones.
V-119RTVA, with V-1118 all call, 18 zones plus
all call.
V-136RTHF*, 36 zones.
V-136RTHF*, with V-1134 all call unit, 34
zones plus all call.
* The V-136RTHF and V-2920 are handsfree page
control units that can also be used for one-way
paging.
Each of the units listed above will drive up to 40
Valcom one-way amplified speaker assemblies per
zone (150 on V-1094A, V-9937, V-1101A, V-2000,
V-2001A, V-2003A and V-2006A). Additional
speakers may be added to a zone by using a
V-1094A. Each V-1094A allows the addition of 150
more amplified speaker assemblies to that zone.
Dimensions
V-1094A: 4.44"H x 2.75"W x 2.88"D
(11.28cm x 6.99cm x 7.32cm)
V-9937: 7.1"H x 4.7"W x 2.1"D
(18.03cm x 11.94cm x 5.33cm)
V-2000: 7.75"H x 5.8"W x 2.6"D
(19.69cm x 14.73cm x 6.6cm)
V-2001A: 7.09"H x 9.0"W x 2.4"D
(18.0cm x 22.86cm x 6.1cm)
V-2003A: 7.13"H x 10.00"W x 3.00"D
(18.1cm x 25.4cm x 7.62cm)
V-2006A: 10.9"H x 13.00"W x 2.69"D
(27.7cm x 33.0cm x 6.83cm)
V-2920: 8.56"H x 11.0"W x 2.35"D
(21.7cm x 27.9cm x 6.0cm)
All Others: 7.13"H x 5.9"W x 2.13"D
(18.11cm x 14.99cm x 5.41cm)
Environment
Control Units:
Temperature 0 to +40 degrees C
Humidity 0-85% non-precipitating
Inside Speakers:
Temperature -20 to +55 degrees C
Humidity 0-95% non-Precipitating
Horn Speakers:
Temperature -20 to +55 degrees C
Humidity 0-95% non-precipitating
Control Unit Power Requirements
Table 1
Control Unit "A" Battery
(milliamps)
"B" Battery
(milliamps)
VPU
V-1094A - 50 -1
V-9937 - 200 -4
V-1101A 50 100 -3
V-2000 Supplies 600 milliamps +12
V-2001A Supplies 1000 milliamps +20
V-2003A Supplies 1000 milliamps +20
V-2006A Supplies 1500 milliamps +30
V-2920 A. C. Line Powered 0
V-1109RTVA 60 250 -6
V-119RTVA 60 250 -6
V-119RTVA/
V-1118
60 750 -16
V-136RTHF 90 500 -12
V-136RTHF/
V-1134
90 1500 -32
Notes for Table 1:
"A" Battery: -21.5 to -26VDC filtered "talk" battery
"B" Battery: -21.5 to -25VDC unfiltered "signal" battery
Filtered "A" battery may be used as both "A"
battery and "B" battery.
Unfiltered "B" battery may not be used in place of
filtered "A" battery.
VPU = Valcom Power Unit.